2023 SOSA - Final Appendices - Final Version.pdf
… 21 3.5 Inter-Island Transmission Assumptions … 36 Appendix 5: Security of Supply Reporting … winter energy demand on a gross basis, inclusive of transmission losses and adjusted for demand response, where … Modelling team and align with those used for transmission planning and strategic planning. They are developed …
2023 SOSA - Final Appendices - Final Version.pdf
(PDF 1.53 MB)
Last updated: 08 May 2023
2023 SOSA - Draft Appendices - Consultation Version.pdf
… 21 3.5 Inter-Island Transmission Assumptions … 36 Appendix 5: Security of Supply Reporting … winter energy demand on a gross basis, inclusive of transmission losses and adjusted for demand response, where … Modelling team and align with those used for transmission planning and strategic planning. They are developed …
2023 SOSA - Draft Appendices - Consultation Version.pdf
(PDF 1.54 MB)
Last updated: 22 Dec 2022
Part D GZ12 West Coast.pdf
… supplied to the region through 110 kV and 66 kV transmission circuits, with two interconnecting transformers … in August 2023. Please refer to the Grid Zone 10 SSF report for more information. SYSTEM SECURITY FORECAST: GRID … 5.1 LIGHT LOAD MITIGATION High voltages can occur when the transmission network is lightly loaded, particularly in …
Part D GZ12 West Coast.pdf
(PDF 605.59 KB)
Last updated: 21 Jan 2025
SO Industry Forum 21 January 2025
… of year, in part driven by outages on grid constraining transmission to upper North Island. • Geothermal at 22%. Te … 3 outage 2 22/02/2025 08/03/2025 Annual Pole 2 outage NZGB Reported NZGB N-1-G margins for 90% weather risk and Base … https://www.transpower.co.nz/system-operator/planning-future/system-security-forecast Security of Supply …
SO Industry Forum 21 January 2025.pdf
(PDF 2.8 MB)
Last updated: 11 Jul 2023
EvolvingSecurityOfSupplyAssessmentsNZ_FINAL.pdf
… of supply, which assesses how much fuel, generation and transmission capacity is available over different time … towards a lower carbon future. 1 See WiTMH monitoring report, New Zealand Steel new electric arc furnace and … MW. Japan – 3% to 8% (a practical metric for short- term planning and coordination as compared to the more “formal” …
EvolvingSecurityOfSupplyAssessmentsNZ_FINAL.pdf
(PDF 621.5 KB)
Last updated: 31 Jul 2024
Appendix B Study Methodology.pdf
… scenarios as the objective of the analysis is to test the transmission system’s limitations. These are during winter … the New Zealand grid is invaluable, and guidance for this report was solicited from those most familiar with these … the forecast developed for Transpower’s 2023 Transmission Planning Report (TPR) is used in these studies. However, it …
Appendix B Study Methodology.pdf
(PDF 517.41 KB)
Last updated: 14 Nov 2023
2024 SOSA - Reference Case and Sensitivities Consultation.pdf
… energy margins assess the adequacy of generation and HVDC transmission capacity to meet expected electricity demand … Document https://www.transpower.co.nz/system-operator/planning-future/security-supply-annual-assessment … mazonaws.com/public/bulk-upload/documents/Market%20insight%20report%20-%20Winter%20Review%20-%2011%20Nov%202022.pdf …
2024 SOSA - Reference Case and Sensitivities Consultation.pdf
(PDF 464.36 KB)
Last updated: 12 Nov 2024
Security of Supply Outlook_30Sep2024.pdf
… and work to improve clarity of the Electricity Risk Curves reporting in relation to contingent storage and Watch … https://www.transpower.co.nz/system-operator/planning-future/security-supply-annual-assessment TRANSPOWER … Transpower as the grid owner cancelled and delayed some transmission outages to release affected generation. The New …
Security of Supply Outlook_30Sep2024.pdf
(PDF 531.53 KB)
Last updated: 15 Jul 2024
Quarterly System performance information - April to June 2024.pdf
… © Transpower New Zealand Limited. All rights reserved. ii Report Purpose To provide information on ancillary service … 09:00 A grid emergency was declared to remove South Island transmission circuits from service to assist with managing … 10:45 A grid emergency was declared to remove North Island transmission circuits from service to assist with managing …
Last updated: 22 Dec 2022
Part D NI Backbone.pdf
… 220 kV grid backbone 2. SYSTEM CONDITIONS Transpower’s 2022 Transmission Planning Report (TPR) identified five system conditions which …
Part D NI Backbone.pdf