Transpower submission on Ministry of Transport Charging our Future.pdf
… infrastructure planning. National direction should set a minimum target, and local councils could increase the target … market requires a competitive, open and non-discriminatory approach to infrastructure, systems and information. Which …
Last updated: 28 Oct 2021
Atiamuri Series Reactors RC Application FINAL 20211027 with appendices.pdf
… .................................................. 16 4.1 Approach to Effects Assessment … of a building are substantially less than 1000m2. 4b.1.3 Minimum Building Setback – front boundary: 0m Complies - … sound levels are given for the approximate setback distances to the façades of the closest receivers. Table 3: …
Last updated: 10 Jan 2024
TP Environmental Performance Handbook - 01 July'21.pdf
… and Emergency Management Ensure noise is kept to a minimum and work within allowable hours. Section 9 – Hours … documented in TP.SS 02.29. If you are uncertain of the best approach to managing a leak, contact Transpower asset … and used oil should be regenerated. � Maintain spray distances. Leaks should not be able to spray outside the …
TP Environmental Performance Handbook - 01 July'21.pdf
(PDF 7.54 MB)
Last updated: 23 Apr 2021
HSW 01.06.pdf
… Risk management principles Transpower’s risk management approach and practices are consistent with AS/NZS ISO … require treatment to reduce them to tolerable levels as a minimum, and to the extent that is reasonably practicable; … of substation security fencing DL 12.02 Transmission lines distances and clearances design standard GP.01.06 General …
HSW 01.06.pdf
(PDF 278.83 KB)
Last updated: 23 Mar 2023
2023 Annual Outage Planning Forum.pdf
… – Whakamaru C (OTA-WKM-C) (only where painting inside the minimum approach distance does painting work require an outage) … 23/24 Outage Assessment Background 1. Public Safety: Ensure minimum safety clearances by preventing sagging due to …
2023 Annual Outage Planning Forum.pdf
(PDF 6.54 MB)
Last updated: 25 Nov 2020
RCP2 Cost Variance Report for Completed Capex Programme and Listed Projects 24 Nov 2020.pdf
… the end of RCP2 as the focus shifted to painting within the Minimum Approach Distance (MAD) which required outages. The impact …
Last updated: 09 Jul 2018
Report%20on%202%20March%202017%20South%20Island%20AUFLS%20Event.pdf
… table below: Actions Key Finding no. Due Status 1. Agree an approach, to be used in future, by protection designers and … available for any subsequent event; • the HVDC link is at minimum modulation and energy co-ordinators were unable to … the HVDC; instead the market system automatically creates minimum and maximum HVDC constraints with every solve. These …
Last updated: 20 Aug 2021
Long list consultation_NZGP1_20 August 2021.pdf
… feedback on our long list of options to meet the need, our approach to reducing that to a short-list and assumptions we … could set the capacity (MW) needs of the battery and the minimum energy (MWh) needs while CNI adds in the energy … is usually more cost effective for transmission over long distances so it is unlikely to be the most cost-effective …
Long list consultation_NZGP1_20 August 2021.pdf
(PDF 2.51 MB)
Last updated: 20 Aug 2021
NZGP1 Long list consultation 20 August 2021.pdf
… feedback on our long list of options to meet the need, our approach to reducing that to a short-list and assumptions we … could set the capacity (MW) needs of the battery and the minimum energy (MWh) needs while CNI adds in the energy … is usually more cost effective for transmission over long distances so it is unlikely to be the most cost-effective …
NZGP1 Long list consultation 20 August 2021.pdf
(PDF 2.59 MB)
Last updated: 15 Apr 2025
USI - Attachment 3 - Benefits modelling
… 1 Benefits modelling approach … - including thermal plant unit commitment and hydro plant minimum flow constraints. SDDP is a well-established model … USI loads generally require power to travel longer distances along less efficient transmission lines compared … with AC power system modelling indicating that a minimum level of Waitaki Valley generation is required to …
USI - Attachment 3 - Benefits modelling.pdf